Whoever tests the alarm gets a reminder each week and records it from their phone in one tap: which call point, and whether it sounded everywhere.
Starts a 14-day trial, no card needed. Then from £19 a month per building. How the reminders work.
Got the last fire alarm service report?
Take a photo of it on your phone. The Venue Record reads the date, works out when the next service is due, and reminds you ahead of it.
Starts a 14-day trial, no card needed. Nothing is filed until you say so.
What it records
One line a week for a year:
- the date the test was done
- which call point was used, by location
- whether every sounder was heard
- any faults, and what was done
- the initials of whoever did it
How to do the weekly test
Set the alarm off from one call point, using the test key, and check it sounds in every part of the building, including the toilets, kitchen and any rooms upstairs. Reset it. Use a different call point the following week, so each one is tested in turn.
Do it at the same time each week if you can, and tell the people in the building first. In a hall used two evenings a week, that usually means whenever someone is next in. Write the real date down.
The weekly test is a common British Standard practice (BS 5839-1), and your fire risk assessment may set it out for your building. It doesn’t replace the service by a competent person, usually every six months.
A fire alarm test notice
A short notice by the main entrance and on the hirers’ noticeboard stops people evacuating, or ignoring a real alarm, when you test. Something like:
Fire alarm test. The fire alarm is tested every [Tuesday] at about [10am]. If the alarm sounds for longer than a minute, or at any other time, treat it as a real fire and leave the building by the nearest exit.
Tell regular hirers too, especially any who use the building at test time. If the alarm is linked to a monitoring centre, let them know before you test, so they don’t call the fire service.
Questions
Do we need a fire alarm test notice?
It isn't a legal requirement, but it's good practice. A notice saying when the weekly test happens stops people evacuating during the test, and makes clear that an alarm at any other time, or one that keeps sounding, is real.
How often should a fire alarm be tested?
Common practice is once a week from a different call point each time, with a service by a competent person at least every six months. Your fire risk assessment sets what your building needs.
What should a fire alarm test log record?
The date, the call point used, whether the alarm was heard throughout the building, any faults and what was done, and who carried out the test.
Not legal advice. Your fire risk assessment, your licence and your insurer set what your building needs.